From monitoring and controlling standby/load management to multi-unit utility paralleling installations, whether you’re on- or off-site, our switchgear is engineered to manage your power system. Automatic Transfer Switches, range from 30A to 5000A and are designed to seamlessly redirect power between your main and backup sources. It’s control for continuous power and continued safety.

7,000
12,000
Cat Customizable Switchgear and Controls

Configuration Application-specific switchgear with control logic designed to meet any customer's sequence of operations. Examples are 3+ Utilities, CHP applications, complex load shed schemes, etc

Modes of Operation All modes of paralleling generator sets to each other and to other sources (utility, alternative fuels, wind, etc) can be supported. Caterpillar generation and control experts can design and program the most complex power schemes to meet your critical pow

Application LV and MV ( 208V - 38 kV) 50 / 60 Hz

Cat EGP Switchgear

Configuration Configurable PLC based switchgear capable of controlling and monitoring multiple generator sets, tie and load breakers in conjunction with downstream transfer switches for standby or emergency applications

Modes of Operation Multi-unit Island and multi-unit standby mode with optional redundant controls and components.

Application LV and MV (208V - 38 kV)

Cat Switchgear

Configuration IP4X

Operating Temperature 35 °C / 40 °C @ 1 hr, option for 0…50 °C (32…122 °F)

Standard Widths 600 mm for ABB Emax2 E2 1600 - 2500A. 750 mm for ABB Emax2 E4 3200 - 4000A. 1200 mm for ABB Emax2 E6 4000 - 6300A.

Cat XLM Switchgear

Configuration Configurable PLC based switchgear capable of controlling and monitoring multiple generator sets, tie, utility and load breakers for utility paralleling applications

Modes of Operation Emergency Standby, Utility Import/Export, Peak shaving, and base load operations with redundant controls and components. Closed transition to/from generator power

Application LV and MV ( 208V - 38 kV

EMCP 4.4 Master Control Panel

Configuration Remote monitoring and control for up to 8 generator sets via high-speed network. Enables paralleling a group of EMCP 4.4 equipped generator sets to a single utility source.

Modes of Operation Emergency standby, island, utility paralleling

Application LV and MV (208V - 38 kV)

Engine Paralleling and Integration Control (EPIC)

Configuration Remote modular paralleling control system (Master Control Panel for the first 2 generator sets and optional tie breaker, separate add-on control panels for up to 8 additional generator sets, utility paralleling control, and distribution control)

Modes of Operation Emergency Standby with redundant master control, Utility paralleling, peak shaving, and closed transition to/from Generator Power (with optional utility control panel)

Application LV and MV (208V-27kV)