D150 GC Generator Set

The image displayed does not reflect the exact machine specifications, including attachments represented in the image on this machine.

D150 GC Generator Set

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Standby Rating
150 ekW
Frequency
60 Hz
Emissions/Fuel Strategy
U.S. EPA Tier 3 Certified
Voltage
208 to 600 Volts
Speed
1800 rpm
Duty Cycle
Standby
Engine Model
C7.1 I-6, 4-Cycle Diesel
Bore
4.1in
Stroke
5.31in
Displacement
428in³
Compression Ratio
16.7:1
Aspiration
Turbocharged, Air to Air Aftercooled
Fuel System
Electronic, Common Rail
Governor Type
ADEM™A4
Length – Maximum
103.7in
Width – Maximum
51.2in
Height – Maximum
52.2in
Dry Weight – Genset (maximum)
3443lb
  • Air Inlet System
    • Air cleaner; light duty with disposable element
  • Control Panels
    • GCCP 1.2 Control panel
  • Cooling System
    • Fan drive, battery charging alternator drive
    • Radiator and cooling fan with guards
    • Coolant drain line with valves
    • Caterpillar extended life coolant
  • Generator And Generator Attachments
    • 12 Leads
    • Segregated low voltage (AC/DC) wiring panel
    • IP23 Protection
    • Tower panel, IP22, bottom cable entry
    • Voltage regulator (single phase sensing)
    • Circuit breaker, IEC, 3 pole, mounted in tower panel
  • Exhaust System
    • Stub pipe, gaskets, raincap and SAE exhaust flange for customer use – shipped loose
  • Fuel System
    • Standard open set fuel tank/base supplied
    • Base, formed steel with single wall integral 24-hour fuel tank
  • Lube System
    • Lubricating oil
    • Oil drain line with valve
  • Mounting System
    • Termination points for coolant and lube oil drain lines
    • Captive linear vibration isolators between base and engine-generator
    • Includes lifting provision and drag points
  • Starting / Charging System
    • 24V battery with rack and cables
  • Governing System
    • Mechanical and electrical governing system – model dependent
  • General
    • Engine and alternator pre-paint, Caterpillar yellow
  • Alternator System
    • R Frame auxiliary winding: R2273L4 SE aux alt 07, aux alt 08 and aux alt 10
    • Anti-condensation heater
    • 3 Phase sensing
    • Quatrature droop king
    • Alternator removal
    • Permanent magnet excitation (PMG)
  • Circuit Breakers
    • Padlockable breaker device
    • 4 Pole 250A, 400A and 630A Circuit breakers
  • Control Panel Options
    • Battery charger
    • Panel mounted audible alarm
    • Emergency stop with key
    • Speed adjust potentiometer
    • Control panel heater
    • Earth leakage (2 wire only)
    • Earth fault (2 wire only)
    • Speed adjust contacts
    • Overload shutdown via breaker
    • Volt free contacts
  • Control System
    • Volt free contacts for common alarm
    • Static battery charger
    • Volt free contacts for generator set running
  • Cooling System
    • Coolant heater
    • Low coolant level shutdown
    • Low coolant temperature
  • Enclosures
    • Sound attenuated level 2 enclosure
  • Mounting Options
    • Electronic governor
    • Residential silencer
    • Industrial silencer removal
    • Silencer installation kit
    • Battery removal
  • Fuel Systems
    • High fuel level alarm
    • Skidbase for CALG enclosure sets
    • Compact skidbase for open sets
    • Open set narrow tankbase
    • Low fuel level alarm
    • DEFRA bunded fuel tank
    • Low fuel level shutdown
  • Test Reports
    • PGS Test report @ 1.0 power factor
    • PGS Test report @ 0.8 power factor
  • General
    • Stone guards/radiator trans flange
  • Power Termination
    • Circuit breaker, IEC, 4 pole
  • Accessories / Miscellaneous
    • Packing case – canopied set
    • Packing case – compact set

Coming Soon