Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
0% FOR 12 MONTHS OR 1.9% FOR 24 MONTHS ON CAT® WORK TOOLS
Get 0% for 12 Months or 1.9% for 24 Months1 on qualifying Cat® Work Tool purchases of $1,000 or more when you use the Cat® Card. Offer valid through December 31, 2026.
Generator set packages include Caterpillar’s voltage
regulator (IVR). IVR includes reactive droop capability, 3-phase voltage sensing,
KVAR / PF modes, RFI suppression, min / max exciter.
Limiter and exciter diode monitor
Alarm acknowledge
Cat connect
Engine cycle crank
Text alarm/event descriptions
Overcurrent (50 / 51)
Accessory module data link
Cat ECS 100
1 Programmable relay outputs (Form C)
Emergency stop pushbutton
Speed adjust
4 Programmable relay outputs (Form A)
Number of I/O varies on options selected
6 Customer programmable digital inputs
Environmental sealed front face
Load histogram feature
Lamp test
PLC functionality
Customizable screens -0 True RMS AC metering, 3-phase, +/-2% accuracy
Digital indication for:
Operating hours
RPM
DC volts
Frequency (Hz)
Coolant temperature
Volts (L-L & L-N)
Oil pressure (psi, kPa or bar)
Amps (per phase & average)
kVAr (per phase, average & percent)
kVA (per phase, average & percent)
kW (per phase, average & percent)
Power factor (per phase & average)
kW-hr (total)
kVAr-hr (total)
High coolant temperature
Overspeed
Failure to start (overcrank)
Warning/shutdown with common LED indication of shutdowns for:
Emergency stop
Low oil pressure
Low coolant level
Low coolant temperature
Programmable protective relaying functions:
Over/under frequency (81 o/u)
Generator phase sequence
Over/under voltage (27 / 59)
Reverse power (kW) (32)
Fuel
Primary fuel filter with integral water separator
Generator
Matched to the performance and output characteristics of Cat engines
IP23 Protection
Power Termination
Busbar
Control Panel
Cat ECS Genset controller
Cooling System
Certified standard PGS provided
Exhaust System
Flanged faced outlet(s)
Dry exhaust manifold
Fuel System
Flexible fuel lines – shipped loose
Fuel cooler; not included with packages without radiator
Secondary fuel filters
Fuel priming pump
General
Caterpillar yellow with high gloss black rails and radiator
Right hand servicing
Flywheel and flywheel housing – SAE No. 00
Paint – Caterpillar yellow except rails and radiators gloss black
SAE standard rotation
Generator And Attachments
Busbar connections, top center mounted, top cable entry
Class H temperature rise at 40C ambient (125C prime / 150C standby)
Low voltage:
NEMA standard hole pattern
Medium voltage:
Anti-condensation space heater
6 Lead
Random wound
Form wound
NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime / 150C standby)
Permanent magnet excitation (PMG)
Class H insulation, Class F temperature rise at 40C ambient (105C prime/130C standby)
Internal excitation (IE)
3 Phase brushless, Salient pole
High voltage:
Winding temperature detectors
Busbar connections, right side extension box, bottom cable entry