The image displayed does not reflect the exact machine specifications, including attachments represented in the image on this machine.

3516B Generator Set

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Prime Power Rating
1825 ekW
Continuous Rating
1640 ekW
Emissions/Fuel Strategy
Low Fuel Consumption
Voltage
380 to 13800 Volts
Frequency
60 Hz
Speed
1800 rpm
Duty Cycle
Prime, Continuous
Maximum Rating
1825 ekW
Minimum Rating
1640 ekW
Engine Model
3516B TA, V-16, 4-Stroke Water-Cooled Diesel
Bore
6.69in
Stroke
7.48in
Displacement
4210.64in
Compression Ratio
14.0:1
Aspiration
TA
Fuel System
Electronic unit injection
Governor Type
Adem™4
Length – Minimum
264.3in
Length – Maximum
264.3in
Width – Minimum
90.1in
Width – Maximum
90.1in
Height – Minimum
94.1in
Height – Maximum
94.1in
Dry Weight – Genset (minimum)
33300lb
Dry Weight – Genset (maximum)
33300lb
  • Air Cleaner
    • Single element with service indicator
  • Starting
    • Heavy duty electric starter(s)
  • Cooling
    • No Radiator
  • Mounting System
    • Rails
  • Controller
    • Cat ECS 100
  • Telematics
    • Ethernet
  • Alternator
    • Random Wound
    • Internal Excitation (IE)
  • Power Termination
    • Busbar
  • Air Cleaner
    • Dual element with service indicator
  • Starting
    • Standard batteries
    • Oversized batteries
    • Battery charger – 10A
    • Battery charger – 20A
    • Battery charger – 40A
    • Air starter(s)
    • Jacket water heater
  • Muffler
    • Industrial grade (15 dB)
  • Mounting System
    • Rubber
    • Spring vibration Isolators
    • Seismic rated vibration isolators
  • Controller
    • Cat ECS 200
    • EMCP 4.4
  • Controller Attachments
    • Local annunciator module
    • Remote annuciator module
    • Expansion I/O module
    • Remote monitoring software
  • Telematics
    • Cellular
  • Extended Service Terms
    • 2 year (Prime)
    • 3 year
    • 5 year
    • 10 year
  • Extended Service Coverage
    • Silver
    • Gold
    • Platinum
    • Platinum plus
  • Alternator
    • Form wound
    • Permanent Magnet (PM) Excitation
  • Alternator Temperature Rise (over 40°c Ambient)
    • 80°C
    • 105°C
    • 125°C/130°C
  • Alternator Output Voltage
    • 440V
    • 480V
    • 600V
    • 2400V
    • 4160V
    • 6300V
    • 6600V
    • 6900V
    • 12470V
    • 13200V
    • 13800V
  • Alternator Attachments
    • Anti-condensation space heater
    • Stator and bearing temperature monitoring and protection
  • Power Termination
    • Circuit breaker
  • Circuit Breaker
    • 1600A
    • 2000A
    • 2500A
    • 3000A
    • 3200A
    • 4000A
    • 5000A
    • Electrically operated
  • Trip Unit
    • LSI
    • LSI-G
    • LSI-P
    • LSIG-P
  • Ancilliary Equipment
    • Automatic transfer switch (ATS)
    • Paralleling switchgear
    • Paralleling controls
  • Certifications
    • IBC seismic certification