DE88 GC Generator Set (60 Hz)

The image displayed does not reflect the exact machine specifications, including attachments represented in the image on this machine.

DE88 GC Generator Set (60 Hz)

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Maximum Rating
80 ekW
Minimum Rating
80 ekW
Emissions/Fuel Strategy
Non Regulated
Voltage
220 to 480 Volts
Frequency
60 Hz
Speed
1800 rpm
Duty Cycle
Standby
Engine Model
C4.4, In-line 4, 4-cycle diesel
Bore
4.1in
Stroke
5in
Displacement
268.5in
Compression Ratio
17.25:1
Aspiration
Turbocharged
Fuel System
Inline
Governor Type
Mechanical
Length – Maximum
89.6in
Width – Maximum
43.3in
Height – Maximum
57.7in
Dry Weight – Genset (maximum)
1245lb
  • Engine
    • C4.4, Inline 4 cylinder, 4 stroke diesel
  • Governor
    • Mechanical governor
  • Alternator
    • A Frame standard alternator
  • Fuel Storage
    • Single wall 8 hour fuel tank
  • Genset Control
    • GCCP 1.1
  • Enclosure
    • Cat GC enclosure
  • Air, Cooling & Exhaust
    • Enclosure silencer
  • General
    • Engine and alternator pre-paint, Caterpillar yellow
  • Auxiliary Supply Voltage
    • 120V
  • Certification
    • Australia, CIS, Gulf Certification
    • Certificate of Conformance
  • Alternator Requirements
    • Space heater
  • Fuel Storage
    • Low fuel level shutdown
    • Single wall tank with containment
    • Dual wall 8 hour fuel tank
    • Low fuel level alarm
    • High fuel level alarm
  • Genset Control
    • Volt free contacts for genset running
    • Earth fault
    • Panel mounted audible alarm
    • USB to RS485 Communications device
    • Emergency stop with key
    • Earth leakage
    • Battery charger
    • Volt free contacts for common alarm
    • Coolant heater
    • Standby Pack (Smart Jacket water heater, Battery charger)
    • Battery
    • Low coolant level shutdown
  • Circuit Breaker
    • 3 Pole Circuit breaker 160A
    • 3 Pole Circuit breaker 125A
    • 3 Pole Circuit breaker 200A
    • 3 Pole Circuit breaker 400A
    • 4 Pole Circuit breaker 160A
    • 4 Pole Circuit breaker 125A
    • 3 Pole Circuit breaker 250A
    • 4 Pole Circuit breaker 250A
    • 4 Pole Circuit breaker 200A
    • Circuit breaker padlock
    • 4 Pole Circuit breaker 400A
    • Neutral earth link
    • Overload via alarm switch on breaker
  • Testing & Packaging
    • PGS Test report @ 1.0 power factor
    • PGS Test report @ 0.8PF

Coming Soon